{"id":11060,"date":"2024-03-26T14:53:05","date_gmt":"2024-03-26T13:53:05","guid":{"rendered":"https:\/\/www.hsvision.de\/?post_type=product&#038;p=11060"},"modified":"2024-03-26T16:21:38","modified_gmt":"2024-03-26T15:21:38","slug":"advanced-post-processing-optional","status":"publish","type":"product","link":"https:\/\/www.hsvision.de\/en\/produkt\/software-en\/digital-image-correlation-dic\/advanced-post-processing-optional\/","title":{"rendered":"Advanced post-processing (optional)"},"content":{"rendered":"<h2>VFM: Material identification with the virtual field method (optional)<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-11037 alignleft\" src=\"https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/VFM-300x172.png\" alt=\"\" width=\"349\" height=\"200\" srcset=\"https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/VFM-300x172.png 300w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/VFM-600x344.png 600w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/VFM-1024x587.png 1024w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/VFM-50x29.png 50w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/VFM-70x40.png 70w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/VFM.png 1437w\" sizes=\"auto, (max-width: 349px) 100vw, 349px\" \/><\/p>\n<ul>\n<li><strong>Complete identification of mechanical material parameters on the basis of full-field measurements<\/strong><\/li>\n<li style=\"text-align: left;\"><strong>Automatic determination of weighting factors in the optimisation solver to maximise parameter sensitivity and minimise the effects of noise<\/strong><\/li>\n<li style=\"text-align: left;\"><strong>Generation of full-field voltage maps<\/strong><\/li>\n<li style=\"text-align: left;\"><strong>Elasticity, plasticity, hyperelasticity, visco-elasticity and visco-plasticity<\/strong><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<div class='w3eden'><!-- WPDM Link Template: Button Template -->\n\n<div class=\"well c2a3\">\n    <div class=\"media\">\n        <div class=\"mr-3\" align=\"left\">\n            <img decoding=\"async\" class=\"wpdm_icon\" alt=\"Icon\" src=\"https:\/\/www.hsvision.de\/wp-content\/plugins\/download-manager\/assets\/file-type-icons\/pdf.svg\" \/>\n        <\/div>\n        <div class=\"media-body\">\n            <h3 class=\"media-heading\" style=\"padding-top: 0px;border:0px;margin: 0 0 5px 0;font-size:12pt;\">\n               MatchID VFM Flyer\n                <\/h3>\n        <\/div>\n        <div class=\"ml-3\" align=\"right\">\n            <a class='wpdm-download-link download-on-click btn btn-primary btn-lg' rel='nofollow' href='#' data-downloadurl=\"https:\/\/www.hsvision.de\/en\/download\/matchid-vfm-flyer\/?wpdmdl=11039&refresh=6a326360bdcf51781687136\">Download<\/a>\n        <\/div>\n    <\/div>\n\n<\/div>\n<style>\n    .well.c2a3 .btn {\n        padding: 11px 30px;\n        font-size: 11pt;\n    }\n\n    .well.c2a3 .media-body {\n        font-size: 11pt;\n    }\n\n    .well.c2a3 .wpdm_icon {\n        height: 42px;\n        width: auto;\n    }<\/style>\n<\/div>\n<p>&nbsp;<\/p>\n<h2>FEVAL: Finite element model validation (optional)<\/h2>\n<p><strong><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-11040 alignleft\" style=\"font-weight: 400;\" src=\"https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/FEVAL-300x165.png\" alt=\"\" width=\"364\" height=\"200\" srcset=\"https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/FEVAL-300x165.png 300w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/FEVAL-600x329.png 600w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/FEVAL-1024x562.png 1024w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/FEVAL-50x27.png 50w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/FEVAL-70x38.png 70w, https:\/\/www.hsvision.de\/wp-content\/uploads\/2024\/03\/FEVAL.png 1220w\" sizes=\"auto, (max-width: 364px) 100vw, 364px\" \/><\/strong><\/p>\n<ul>\n<li><strong>Mesh and node converter for Abaqus, Ansys, Siemens, &#8230; for shell\/volume and linear\/square formulations<\/strong><\/li>\n<li><strong>Processing the FEA data through the same filters (subset, shape functions, interpolation, etc.) as the real experimental data<\/strong><\/li>\n<li><strong>This levelling approach guarantees a true digital twin<\/strong><\/li>\n<li><strong>Determination of the frame alignment by including the calibration parameters and reference points<\/strong><\/li>\n<li><strong>Generation of full-field error and validation maps showing possible model errors<\/strong><\/li>\n<li><strong>Batch processing available so that the finite element model can be updated<\/strong><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<div class='w3eden'><!-- WPDM Link Template: Button Template -->\n\n<div class=\"well c2a3\">\n    <div class=\"media\">\n        <div class=\"mr-3\" align=\"left\">\n            <img decoding=\"async\" class=\"wpdm_icon\" alt=\"Icon\" src=\"https:\/\/www.hsvision.de\/wp-content\/plugins\/download-manager\/assets\/file-type-icons\/pdf.svg\" \/>\n        <\/div>\n        <div class=\"media-body\">\n            <h3 class=\"media-heading\" style=\"padding-top: 0px;border:0px;margin: 0 0 5px 0;font-size:12pt;\">\n               MatchID FEA Flyer\n                <\/h3>\n        <\/div>\n        <div class=\"ml-3\" align=\"right\">\n            <a class='wpdm-download-link download-on-click btn btn-primary btn-lg' rel='nofollow' href='#' data-downloadurl=\"https:\/\/www.hsvision.de\/en\/download\/matchid-fea-flyer\/?wpdmdl=11042&refresh=6a326360c0c281781687136\">Download<\/a>\n        <\/div>\n    <\/div>\n\n<\/div>\n<style>\n    .well.c2a3 .btn {\n        padding: 11px 30px;\n        font-size: 11pt;\n    }\n\n    .well.c2a3 .media-body {\n        font-size: 11pt;\n    }\n\n    .well.c2a3 .wpdm_icon {\n        height: 42px;\n        width: auto;\n    }<\/style>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>VFM: Material identification with the virtual field method (optional) Complete identification of mechanical material parameters on the basis of full-field measurements Automatic determination of weighting factors in the optimisation solver to maximise parameter sensitivity and minimise the effects of noise Generation of full-field voltage maps Elasticity, plasticity, hyperelasticity, visco-elasticity and visco-plasticity &nbsp; &nbsp; &nbsp; FEVAL:&#8230;<\/p>\n","protected":false},"featured_media":11023,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[126],"product_tag":[],"class_list":["post-11060","product","type-product","status-publish","has-post-thumbnail","product_cat-digital-image-correlation-dic","first","instock","shipping-taxable","product-type-simple"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.hsvision.de\/en\/wp-json\/wp\/v2\/product\/11060","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hsvision.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hsvision.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hsvision.de\/en\/wp-json\/wp\/v2\/media\/11023"}],"wp:attachment":[{"href":"https:\/\/www.hsvision.de\/en\/wp-json\/wp\/v2\/media?parent=11060"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hsvision.de\/en\/wp-json\/wp\/v2\/product_brand?post=11060"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hsvision.de\/en\/wp-json\/wp\/v2\/product_cat?post=11060"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hsvision.de\/en\/wp-json\/wp\/v2\/product_tag?post=11060"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}